Sizes, cooling capacities and connection values in a clear overview.

Select cooking function, row arrangement and refrigerant. The table shows the confirmed IK sizes and calculates 15 kW cooling capacity per loading trolley.

01

Configure version

The selection serves as a technical planning basis for the blast chilling system.

Door configuration
Pass-through system with front and rear doors. System length +200 mm.
Cooking function
Loading
Selected configurationWithout cooking function · single row · Glycol

Cooling capacity · 15 kW cooling capacity per loading trolley at −15 °C flow temperature.

An additional heating coil extends the intensive cooling system with cooking and heat-treatment functions. Depending on the configuration, heating is provided by HP steam, electricity or gas/oil. Heat treatment and subsequent intensive cooling can thus take place in the same system.

02

Capacities and dimensions

TypeTrolleysTrolley dimensionsSystem dimensionsCooling capacityElectrical connected load
IK 3.0001single row1000 x 1000 x 2000 mmB 1450 x D 1290 x H 2820 mmSystem housing+ 300 mm air recirculation motor15 kWRefrigerant · GlycolFlow temperature −15 °C4 kW
IK 6.0002single row1000 x 1000 x 2000 mmB 1450 x D 2350 x H 2820 mmSystem housing+ 300 mm air recirculation motor30 kWRefrigerant · GlycolFlow temperature −15 °C7 kW
IK 9.0003single row1000 x 1000 x 2000 mmB 1450 x D 3440 x H 2820 mmSystem housing+ 300 mm air recirculation motor45 kWRefrigerant · GlycolFlow temperature −15 °C10 kW
IK 12.0004single row1000 x 1000 x 2000 mmB 1450 x D 4520 x H 2820 mmSystem housing+ 300 mm air recirculation motor60 kWRefrigerant · GlycolFlow temperature −15 °C13 kW
IK 15.0005single row1000 x 1000 x 2000 mmB 1450 x D 5600 x H 2820 mmSystem housing+ 300 mm air recirculation motor75 kWRefrigerant · GlycolFlow temperature −15 °C16 kW
IK 18.0006single row1000 x 1000 x 2000 mmB 1450 x D 6680 x H 2820 mmSystem housing+ 300 mm air recirculation motor90 kWRefrigerant · GlycolFlow temperature −15 °C19 kW
IK 24.0008single row1000 x 1000 x 2000 mmB 1450 x D 8840 x H 2820 mmSystem housing+ 300 mm air recirculation motor120 kWRefrigerant · GlycolFlow temperature −15 °C25 kW
IK 30.00010single row1000 x 1000 x 2000 mmB 1450 x D 11000 x H 2820 mmSystem housing+ 300 mm air recirculation motor150 kWRefrigerant · GlycolFlow temperature −15 °C31 kW
IK 36.00012single row1000 x 1000 x 2000 mmB 1450 x D 13160 x H 2820 mmSystem housing+ 300 mm air recirculation motor180 kWRefrigerant · GlycolFlow temperature −15 °C37 kW
Planning note

Height is specified separately for the system housing and the additional 300 mm for the air recirculation motor. Cooling capacity applies at −15 °C flow temperature. All values are guidelines; each SORGO blast chilling system is individually designed and manufactured.