Sizes, cooling capacities and connection values in a clear overview.
Select cooking function, row arrangement and refrigerant. The table shows the confirmed IK sizes and calculates 15 kW cooling capacity per loading trolley.
Configure version
The selection serves as a technical planning basis for the blast chilling system.
Cooling capacity · 15 kW cooling capacity per loading trolley at −15 °C flow temperature.
An additional heating coil extends the intensive cooling system with cooking and heat-treatment functions. Depending on the configuration, heating is provided by HP steam, electricity or gas/oil. Heat treatment and subsequent intensive cooling can thus take place in the same system.
Capacities and dimensions
| Type | Trolleys | Trolley dimensions | System dimensions | Cooling capacity | Electrical connected load |
|---|---|---|---|---|---|
| IK 3.000 | 1single row | 1000 x 1000 x 2000 mm | B 1450 x D 1290 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 15 kWRefrigerant · GlycolFlow temperature −15 °C | 4 kW |
| IK 6.000 | 2single row | 1000 x 1000 x 2000 mm | B 1450 x D 2350 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 30 kWRefrigerant · GlycolFlow temperature −15 °C | 7 kW |
| IK 9.000 | 3single row | 1000 x 1000 x 2000 mm | B 1450 x D 3440 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 45 kWRefrigerant · GlycolFlow temperature −15 °C | 10 kW |
| IK 12.000 | 4single row | 1000 x 1000 x 2000 mm | B 1450 x D 4520 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 60 kWRefrigerant · GlycolFlow temperature −15 °C | 13 kW |
| IK 15.000 | 5single row | 1000 x 1000 x 2000 mm | B 1450 x D 5600 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 75 kWRefrigerant · GlycolFlow temperature −15 °C | 16 kW |
| IK 18.000 | 6single row | 1000 x 1000 x 2000 mm | B 1450 x D 6680 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 90 kWRefrigerant · GlycolFlow temperature −15 °C | 19 kW |
| IK 24.000 | 8single row | 1000 x 1000 x 2000 mm | B 1450 x D 8840 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 120 kWRefrigerant · GlycolFlow temperature −15 °C | 25 kW |
| IK 30.000 | 10single row | 1000 x 1000 x 2000 mm | B 1450 x D 11000 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 150 kWRefrigerant · GlycolFlow temperature −15 °C | 31 kW |
| IK 36.000 | 12single row | 1000 x 1000 x 2000 mm | B 1450 x D 13160 x H 2820 mmSystem housing+ 300 mm air recirculation motor | 180 kWRefrigerant · GlycolFlow temperature −15 °C | 37 kW |
Height is specified separately for the system housing and the additional 300 mm for the air recirculation motor. Cooling capacity applies at −15 °C flow temperature. All values are guidelines; each SORGO blast chilling system is individually designed and manufactured.