TECHNICAL DESIGN

Sizes and capacities in a clear overview.

Select the trolley count for the continuous line. Section 1 and section 2 are automatically designed with equal capacity; capacities, connections and dimensions update together.

01

Configure version

One selection controls both process sections connected by the transfer airlock.

Equal trolley count in both sections · Only trolley size 1,000 × 1,000 × 2,000 mm
Door system
01

Section 1

Curing colour development & pre-dryingSmokingCooking & thermal processing
Heating type
02

Section 2

ShoweringChilling & crust freezing
Section 2 cooking function
02

Capacities and dimensions · Section 1

Continuous 2+2

Curing colour development & pre-dryingSmokingCooking & thermal processing
TypeTrolleysTrolley dimensionsSystem dimensionsHeat supplyCooking / humidificationElectrical connected load
HR 6.000Smoking/cooking section2Section 11,000 × 1,000 × 2,000 mmB 1450 x D 2350 x H 2820 mmSystem housing+ 300 mm air recirculation motor60 kWHeating capacity · ElectricCold or hot water supplyElectric72,5 kWFriction smoke · Standard versionSmoke generator electrical load: 5,5 kW
03

Capacities and dimensions · Section 2

Continuous 2+2

ShoweringChilling & crust freezing
TypeTrolleysTrolley dimensionsSystem dimensionsHeating capacity / cookingCooling capacityElectrical connected load
IK 6.000Blast chilling section2Section 21,000 × 1,000 × 2,000 mmB 1450 x D 2350 x H 2820 mmSystem housing+ 300 mm air recirculation motorWithout cooking functionNot selected30 kWRefrigerant · Glycol15 kW per trolley at −15 °C flow temperature7 kW
04

Overall overview

Total values are based on two equally sized sections.

TypeContinuous 2+2Section 1 + Section 2
Total trolley positions42 + 2
Indicative overall system dimensionsB 1450 × D 4700 × H 3120 mmSection 1 + Section 2
Total electrical connected load79,5 kW72,5 + 7 kW
Process capacitiesSection 1: 60 kW heating capacitySection 2: 30 kW cooling capacity
Planning note

Overall dimensions use the common width and height of both sections; depth is the sum of sections 1 and 2. The transfer airlock, door system, transport and local installation conditions are defined in the project. All performance and dimensional data are indicative.

The complete table with your current selection as an A3 landscape PDF.